• Universal AC Input 90-264VAC
• Wattage: 11-12.6W
• Output Voltage: 3.6-32V
• AC Plug Standard: UK
• Dimension(mm): 79.4(L) x 55(W) x42(H)
• High Reliability, High Efficiency, Long Operation Life
• Protection: Over Temperature, Over Voltage, Overload, Short Circuit
• 2 Years Warranty
Spec. Download
• OUTPUT |
||||||||
DC Voltage note.2 |
3.6-5.5V |
5.6-8.9V |
9.0V |
9.1-11.8V |
11.9-12.6V |
12.7-19.0V |
19.1-30.7V |
30.8-32.0V |
Rated Current |
3.06A |
1.99A |
1.4A |
1.32A |
1.06A |
0.95A |
0.63A |
0.39A |
Current Range |
0-3.06A |
0-1.99A |
0-1.4A |
0-1.32A |
0-1.06A |
0-0.95A |
0-0.63A |
0-0.39A |
Rated Power(max.) |
11W |
11.16W |
12.6W |
12W |
12.6W |
12.06W |
12W |
12.16W |
Ripple&Noise(max.) note.3 |
150mV |
150mV |
150mV |
150mV |
150mV |
150mV |
150mV |
150mV |
Voltage Tolerance note.4 |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
Line Regulation note.5 |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
Load Regulation note.6 |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
Start Delay, Rise, Hold up time |
≤3000ms, 25ms, 5ms@230Vac / ≤5000ms, 25ms, 5ms@115Vac |
|||||||
• INPUT |
||||||||
Voltage Range |
90Vac ~ 264Vac |
|||||||
Frequency Range |
47 ~ 63Hz |
|||||||
Efficiency(Typ.) |
≥82.96% |
≥82.96% |
≥82.96% |
≥82.96% |
≥82.96% |
≥82.96% |
≥82.96% |
≥82.96% |
AC Current |
0.4A/ 240VAC |
|||||||
Inrush Current(max.) |
cold start @25℃ 60A/ 240VAC |
|||||||
Leakage Current(max.) |
≤0.25mA/ 240VAC |